Electromagnetic valve 1160 is used for gasoline supply remote control.
Workspace |
gasoline B-70 or air |
||
Workspace temperature |
from -60 up to +90ºC |
||
Direct current circuit voltage |
27±2.7 V |
||
Minimum response voltage under valve incoming pressure 0.196 MPa (2kgs/ cm2) |
not more than 18 V |
||
Current at the voltage of 27V environment temperature 20ºC |
not more than 0.31 mA |
||
Complete product mass |
not more than 0.47 kg |